Abstract:
Surrounding rock masses in deep coal mines are prone to dynamic instability under the combined effects of excavation-induced unloading and low-frequency disturbance. Confining-pressure unloading tests and tests combining staged confining-pressure unloading with dynamic-load disturbance were conducted using a ZST-1500 microcomputer-controlled electro-hydraulic servo testing system for adaptive static-dynamic coupled loading of coal and rock. The mechanical response, damage characteristics, failure modes, and energy evolution of unloaded sandstone under low-frequency disturbance at different preload levels were systematically examined. The results show that: Under low-frequency disturbance, the irreversible strain of unloaded sandstone evolves from a logarithmic pattern to a U-shaped pattern with increasing preload level, while its strength first increases and then decreases. The deformation modulus of unloaded sandstone generally exhibits a staged evolution characterized by unloading-induced deterioration, a sudden disturbance-induced decrease, staged recovery, and subsequent deterioration. During disturbance, at preload levels of 0.30
σp–0.60
σp, the dynamic loading modulus increases rapidly and then grows slowly, whereas the dynamic unloading modulus decreases rapidly and then recovers slowly. At 0.75
σp, both moduli decrease simultaneously in the later cycles. At 0.90
σp, the loading modulus rises sharply and then drops abruptly, whereas the unloading modulus drops sharply and then rises abruptly. As the preload level at which disturbance is applied increases, the macroscopic failure mode of unloaded sandstone changes from single shear failure to combined tensile-shear failure. Under high preload conditions, the specimens exhibit complex shear crack networks and pronounced localized fragmentation. With increasing preload level, the average input energy and average elastic energy during disturbance decrease exponentially, whereas the average dissipated energy peaks at 0.75
σp. The linear-to-nonlinear transition points of the energy storage coefficient
Ke and the lateral-to-axial dissipation ratio
η, together with the trough points of
η, can be used to delineate the deterioration and instability early-warning intervals of unloaded sandstone under low-frequency disturbance. These intervals shorten as the preload level increases.