对煤矿防隔水煤(岩)柱留设规定的十二条商榷

Discussion on twelve points of regulations regarding setting of waterproof coal (rock) pillars in coal mines

  • 摘要: 《煤矿防治水细则》《建筑物、水体、铁路及主要井巷煤柱留设与压煤开采规范》既是煤矿防治水工作的基石,也是最高技术准则,其权威性来源于其科学性和严谨性。为了维护规程(规范)的权威性,使其更好地指导煤矿防隔水煤(岩)柱留设,对《细则》附录六以及《三下开采规范》附录4提出商榷意见:一是例图表意模糊,如《细则》附图6-3c中辅助线绘制标准是什么,由于表意模糊造成L1L2无解等,需要修改例图。二是计算公式错误,如《细则》附6-5公式不正确;《细则》附6-8公式经推导无意义;《三下开采规范》给出的“含水层顶部有充填阻水带”防隔水煤(岩)柱表达式及附图均错误等,需修改表达式及附图。三是影响因素疏漏,如《细则》中对通水钻孔防隔水煤(岩)柱留设未考虑采动覆岩移动角,需要修改例图和计算公式。四是参考标准不统一,如《细则》中附6-6公式、附6-8公式均为突水系数公式的“借用”,但“借用”标准不统一,建议统一标准。五是参数不明确,如“λ为水压和岩柱宽度的比值”中“岩柱”概念及水压单位不明确,造成公式无解或无法适用;相邻矿井防隔水煤(岩)柱防范对象(水源)不明确,需要明确适用条件;以断层为界的相邻矿井防隔水煤(岩)柱留设因矿井“界线”不明而脱离实际,成了单纯意义上的断层防隔水煤(岩)柱留设等。六是标题概括不恰当,如《细则》附录六之二与附录六之三这2个标题未抓住问题的本质区别;附录六之三的大标题与其控制下的第2小标题相矛盾(大标题为导水断层,大标题下第2小标题仅适用于不导水断层)应予纠正;附录六之四的大标题与其控制下的第2小标题相矛盾(大标题为导水断层,小标题为不导水断层),需要修改标题等。七是防隔水煤(岩)柱两端点起算标准混乱,有的以煤层底板与断层面交点为准,有的以煤层顶板与断层面交点为准等,不单纯是例图规范性问题,还关系到计算公式是否正确、有解的问题,如《细则》附6-4公式未考虑煤层厚度等,需要修正公式。八是概念界定模糊,如导水裂隙带高度指的是竖直高度还是法线高度不明确,导水裂隙带高度计算公式及附图均表明导水裂隙带包括垮落带,与名词解释(导水裂隙带不包括垮落带)相矛盾等,建议根据煤层倾角大小进一步明确导水裂隙带高度概念,并厘清导水裂隙带与导水裂隙带高度两者区别;防隔水煤(岩)柱宽度指的是水平宽度还是倾斜宽度需要明确;《细则》附图6-8b导水裂隙带从煤层底板起算,存在概念上错误等。九是适用条件笼统,如煤层露头风化带的防隔水煤(岩)柱留设等,需要进一步明确留设煤柱的适用条件;例图6-3c仅适用于不导水断层,应予纠正。十是例图错误,如《细则》附图6-7将顶板防隔水煤(岩)柱划为采空区;《细则》附图6-8a中Ls长度所指端点不详,需要修改附图等。十一是例图缺失,如《细则》附录六之二遗漏了“含水断层”例图,导致含水断层概念不明确,需要增加例图。十二是顾此失彼,如《细则》附图6-8a等仅考虑一矿开采不得破坏相邻矿井防隔水煤(岩)柱这个原则,却忽视了一矿开采对导水断层本身的破坏,需要修改例图并增加计算公式。

     

    Abstract: “Detailed Rules for Water Prevention and Control in Coal Mines” and “Code for the Setting of Coal Pillars and Coal Mining in Buildings, Water Bodies, Railways and Main Mines” are not only the cornerstone of coal mine water prevention and control work, but also the highest technical standards. Their authority comes from their scientific and rigorous nature. In order to maintain the authority of the regulations (norms) and better guide the retention of water resistant coal (rock) pillars in coal mines, twelve opinions on the provisions of Appendix 6 of “Detailed Rules” and Appendix 4 of “Three Down Mining Norms” are proposed for discussion: firstly, the meaning of the example diagram is vague, such as what is the standard for drawing auxiliary lines in Appendix 6-3c of “Detailed Rules” Due to the vague meaning, L1 and L2 have no solution, and the example diagram needs to be modified. Secondly, there is an error in the calculation formula, such as the incorrect formula in Appendix 6-5 of “Detailed Rules”, The formulas in Annex 6-8 of Detailed Rules are meaningless after deduction. The expression and attached diagram for the waterproof coal (rock) pillar with a filling water blocking zone at the top of the aquifer given in the “Three Bottom Mining Standards” are incorrect and need to be modified. The third issue is the omission of influencing factors, such as the “Detailed Rules” which did not take into account the movement angle of the overlying strata during mining when setting up water resistant coal (rock) columns for water drilling. Therefore, it is necessary to modify the example diagram and calculation formula. The fourth issue is that the reference standards are not unified. For example, formulas 6-6 and 6-8 in the “Detailed Rules” are both “borrowed” from the formula for sudden water coefficient, but the “borrowed” standards are not unified. It is recommended to unify the standards. Fifth, the parameters are not clear, such as the concept of “rock column” and the unit of water pressure in “λ is the ratio of water pressure to rock column width”, which results in the formula having no solution or being unable to apply; The object (water source) to be protected against water blocking coal (rock) pillars in adjacent mines is unclear, and the applicable conditions need to be clarified; The retention of water resistant coal (rock) pillars in adjacent mines bounded by faults is detached from reality due to the unclear “boundary” of the mine, and has become a simple problem of retaining water resistant coal (rock) pillars on faults. Sixth, the title summary is inappropriate, such as Appendix 6-2 and Appendix 6-3 of the Detailed Rules, which fail to grasp the essential difference of the problem; The main title of Appendix 6-3 contradicts the second subheading under its control (the main title is for water conducting faults, and the second subheading under the main title only applies to non water conducting faults) and should be corrected; The main title of Appendix 6-4 conflicts with the second subheading under its control (the main title is water conducting fault, and the subheading is non water conducting fault), and the title needs to be modified. The seventh issue is the confusion of the starting standards for the two ends of the waterproof coal (rock) pillar. Some are based on the intersection point between the coal seam floor and the fault plane, while others are based on the intersection point between the coal seam roof and the fault plane. This is not just a normative issue, but also related to whether the calculation formula is correct and has a solution. For example, the formula in Annex 6-4 of the Detailed Rules does not consider the thickness of the coal seam and needs to be revised. The eighth issue is the vague definition of the concept, such as whether the height of the water conducting fracture zone refers to the vertical height or the normal height being unclear. The calculation formula and accompanying drawings for the height of the water conducting fracture zone indicate that it includes urban collapse zones, which contradicts the explanation of the term (the water conducting fracture zone does not include collapse zones). It is recommended to further clarify the concept of the height of the water conducting fracture zone based on the dip angle of the coal seam, and clarify the difference between the height of the water conducting fracture zone and the height of the water conducting fracture zone. It is necessary to clarify whether the width of the waterproof coal (rock) pillar refers to the horizontal width or the inclined width. There are conceptual errors in the calculation of the water conducting fractured zone from the coal seam floor in Figure 6-8b of the Detailed Rules. The ninth is that the applicable conditions are vague, such as the retention of water-resistant coal (rock) pillars in the weathered zone of coal seam outcrops, and further clarification is needed on the applicable conditions for retaining coal pillars. Example figure 6-3c is only applicable to non water conducting faults and should be pre corrected. Ten is an error in the example diagram, as shown in Figure 6-7 of the Detailed Rules, which classify the roof waterproof coal (rock) pillar as a goaf. The endpoint of Ls length referred to in Figure 6-8a of the Detailed Rules is unknown and needs to be modified. Eleven is the lack of example diagrams, such as the omission of the example diagram of “water bearing faults” in Appendix 6-2 of “Detailed Rules”, which leads to unclear concepts of water bearing faults and requires the addition of example diagrams. Twelve is to focus on one aspect at the expense of another, as shown in Figure 6-8a of the “Detailed Rules”, which only considers the principle that mining one mine must not damage the adjacent mine’s waterproof coal (rock) pillars, but ignores the damage of mining one mine to the water conducting fault itself. It is necessary to modify the example diagram and add calculation formulas.

     

/

返回文章
返回