三维电极组合Fenton试剂处理焦化废水效果分析
Analysis on Deep Treatment Effect of Coking Waste Water with 3D Electrode Combined Fenton Reagent
-
摘要: 采用三维电极组合Fenton试剂对经过二级生化处理后的焦化废水进行深度处理,在三维电极参数一定的条件下,考察了废水中影响TOC去除率的影响因素及废水处理效果,并与普通三维电极法TOC去除效果进行对比。通过单因素试验确定的反应体系中各参数的最佳值如下:pH为3.5,H2O2投加量为17.6 mmol/L,反应时间90 min,FeSO4.7H2O投加量3.5 mmol/L,在此条件下,TOC去除率可达51.7%。紫外可见吸收光谱分析结果表明:废水中有机物彻底发生了降解矿化,这为三维电极组合Fenton试剂工艺在焦化废水深度处理中的工程应用提供了参考依据。Abstract: The 3D electrode combined Fenton reagent was applied to the deep treatment of the coking waste water after the secondary biochemistry treatment.Und er the certain condition of the 3D electrode parameters, the factors affected to the TOC removal rate of the waste water and the waste water treatment effect were inves tigated and a comparison was conducted to the TOC removal effect of the conventional 3D electrode method.With the single factor experiments conducted, the optimum value of each parameter in the reaction system was determined as the followings: the pH value was 3.5, the H2O2 added value was 17.6 mmol/L, the reaction time was 90 min and the FeSO4.7H2O added value was 3.5 mmol/L.Under the circumstances, the TOC removal rate could be reached at 51.7%.The results of the ultraviolet abs orption spectrum analysis showed that the degradation and mineralization occurred on the organics in the waste water and thus could provide the reference basis to the 3D electrode combined Fenton reagent technology applied to the deep treatment of the coking waste water.
下载: