高级检索
范喜生. 矿用自动复位式风井防爆门研究[J]. 煤炭科学技术, 2012, (6).
引用本文: 范喜生. 矿用自动复位式风井防爆门研究[J]. 煤炭科学技术, 2012, (6).
Research on Mine Automatic Resetting Type Flame Proof Door of Ventilation Shaft[J]. COAL SCIENCE AND TECHNOLOGY, 2012, (6).
Citation: Research on Mine Automatic Resetting Type Flame Proof Door of Ventilation Shaft[J]. COAL SCIENCE AND TECHNOLOGY, 2012, (6).

矿用自动复位式风井防爆门研究

Research on Mine Automatic Resetting Type Flame Proof Door of Ventilation Shaft

  • 摘要: 针对煤矿井下发生爆炸时,传统防爆门飞离井口、容易造成井下大范围人员伤亡的问题,研发了自动复位式风井防爆门系列产品,介绍了其防漏风措施,提出了由风机叶片强度反求防爆门受到的爆炸冲击载荷的方法,给出了防爆门梁(柱)和门板与梁(柱)连接部位强度的计算式以及根据风井负压确定门板厚度的计算式等。该产品平时密封可靠;停风时自动开启实施自然通风,恢复供风时自动关闭;发生爆炸时迅速开启保护主要通风机,爆炸过后自动复位,迅速恢复通风系统,给遇险人员自救和应急救援创造有力条件。

     

    Abstract: In order to prevent the personnel casualties caused by the traditional flame proof door flying from the mine shaft mouth when a underground mine explos ion made, a series products of the automatic resetting type flame proof door of the mine ventilation shaft were researched and developed. The paper introduced the air | eakage measures, proposed that the blade strength of the fan was applied to calculate the explosion impact load on the flame proof door. Thus the formula of the conne ction part strength between the beam (column) and the door plate and beam (column) of the flame proof door and the formula of the door plate thickness set with the ne gative pressure of the ventilation shaft were provided.The automatic resetting type flame proof door of the mine ventilation shaft was reliably sealed in normal time.Whe n the mine ventilation stopped, the door would be automatically opened for natural ventilation.When the mine ventilation reset, the door would be automatically closed. When a explosion occurred, the protection for the main ventilators would be rapidly opened.When the explosion passed, the door would be automatically reset and the mine ventilation system would rapidly recovered.Thus a powerful condition would be created for the self rescue and emergency rescue of the refuges.

     

/

返回文章
返回